<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-31 07-52-04
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 57 dBuV SANDELS
Pilot RDS Phase Difference
6.1 kHz 5.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 23 kHz 5380 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,7 dBr 3,73 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 23 kHz MIN: 12 kHz % above 76 kHz: 0,0000 Acquired: 2025/01/31 7.51.00 Total samples: 5380 Equivalent time: 0:04:29 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 6,4 dBr MIN: 1,7 dBr AVE: 3,73 dBr % above 12,2 dBr: 0,0 Last value: 2,1 dBr (2025/01/31 7.51.00) 07.38 07.40 07.42 07.44 07.46 07.48 07.50 0 2 4 6 Pm [dBr]